If the content is not available in your preferred language, please contact us by e-mail.
Niedernhausen WWTP
These should be shut down, disassembled and the scraper should be modified, so that a safe winter operation is ensured.
Challenge
For this purpose, the old, fully-rubberized driving units were dismantled and replaced with new, maintenance-friendly stainless steel units with track rollers and pinions.
The reconstruction was carried out with flooded tanks, in order to keep the failure time as low as possible.
Solution
Humidity or temperature measurements to monitor the winter equipment as well as the storage of de-icing fluids and required devices are no longer necessary.
The stress of the concrete top of the tank by anti-freeze and tire pressure was eliminated.
Key Features
Customer
Abwasserverband Main Taunus
65719 Hofheim am Taunus
Delivery
December 2014
Advatages
- Fault-free winter operation
- Minimum maintenance effort
- Elimination of antifreeze, brushing, etc.
- Energy saving to alternative heated driving surface
- Protection of the crowning of the tank
Technical Data
Diameter of the tank: 37 m
Drive power: 0,55 kW
Material:
Undercarriages: 1.4301
Rail and rack: galvanized steel.
Locations and Contact
Europe
Aqseptence Group GmbH, Aarbergen
Sales and Manufacturing Location
Passavant-Geiger-Strasse 1
65326 Aarbergen
Germany
Tel: +49 6120 280
Fax: +49 6120 28 2182
info.passavant@aqseptence.com