Intech Aqualogic & Enerlogic

Aqualogic® control systems offer customized solutions to individual optimization tasks in the operation of sewage treatment plants. They enable flexible use of the required measuring technology and achieve optimal discharge values coupled with low energy consumption and reduced operational costs.

Enerlogic® ensures maximal aeration energy savings while simultaneously achieving best cleaning performance and stable plant operation.

Unique Selling Point

  •     Scalable for every plant size
  •     Able to use sensors of different suppliers
  •     Highly flexible
  •     Usable for all plant sizes and nearly all process types
  •     Modular program structure - functions/modules can be added step by step.
  •     Load-dependend oxygen set point
  •     Sludge age control

Insights

The load fluctuates considerably in sewage treatment plants as a result of customary daily use, seasonal influences and commercial inflows. Natural events, such as rainfall or periods of drought also lead to peak load and low load periods which call for flexibility of action. Aqualogic® control systems calculate the ideal regulation for individual operational units on the basis of Fuzzy Logic.
This mathematical method, which is modelled on our human way of thinking, can meet the most diverse demands due to its creation of an ideal operational performance. The partially conflicting requirements of the various cleaning processes can thus be optimally met and, for example, intermittent or continuous aeration achieved. The high level of transparency and ease of operation of Aqualogic® enable the user to adapt the system and include experiences previously gained.
Aqualogic® is flexibly adjusted to both existing and desired measuring technology. Many operating companies opt for a regulation of oxygen input by means of the measuring signals oxygen, temperature, ammonium and nitrate. Further signals (such as e.g. feed volume, phosphate, filling level, etc.) can be practically integrated according to the specific application, in order to meet the demands of more complex systems.
Moreover, the organic load can be determined by means of the integrated consumption controller and optimal carbon denitrification ensured. A simple control variant based on oxygen, redox potential and temperature is also possible for smaller plants.
The scope of an Aqualogic® installation is determined by the requirements of the wastewater treatment plant and the needs of the operating company. The Aqualogic® software can be installed on an existing process control computer and easily integrated into the existing automation level of the plant. In addition to the software, complete system solutions can also include PC and SPS technology and also sensor, air blower, conduit and aeration technology.

The Enerlogic® control software is modular designed and configured to suit the specific requirements of each individual wastewater treatment plant. Existing Aqualogic® systems can be converted easily to Enerlogic®. Important input variables in this context are ammonia and nitrate concentrations in the activation stage and frequently the solids concentration. In addition to a variation of aerated and non-aerated phases that meets needs as closely as possible, Enerlogic® also serves to vary the oxygen concentration in the activation phase according to loading, which further optimizes energy input. This means that, for example, during night-time off-peak periods or in the event of longer rain fall, the activation of many plants can be carried out with significantly lower oxygen concentrations. 
Furthermore, Enerlogic® also takes into consideration the current basal metabolic rate of the microorganisms, i.e. the so-called endogenous respiration.
Dynamic sludge age regulation is available as another Enerlogic® module. It is used to set the dry solids content in the aeration tank fully automatically, depending on loading and temperature at a given time. Excessive dry solids content is effectively prevented. Depending on the system, considerable savings potential can be tapped, as each gram above the ideal dry solids content corresponds to an increase of approx. 10 % in additional aeration energy consumption.

Solution

Energy and Prozess Efficiency

The various – partly counter-directional – processes in wastewater treatment plants place heavy demands on automation. A comprehensive approach is, required to ensure efficiency in the implementation of optimization measures. This is the...

View

Ginsheim-Gustavsburg WWTP

The wastewater treatment plant Ginsheim-Gustavsburg treats the sewage of the city of Ginsheim-Gustavsburg as well as of the commune Bischofsheim. The system is constructed for a population equivalent (PE) of 32,500 and is currently...

View

Emden WWTP

The main wastewater treatment plant of Emden in its current form was commissioned in 1983. The plant, which is aerobically stabilised and fed by a separate sewer system is designed for a population equivalent (PE) of 90,000 and charged...

View

Erwitte-Nord WWTP

Further improvement and homogenisation of the already satisfying nitrogen outlet values as well as savings in flocculants and energy consumption. Easy handling of the control system and high reliability was desirable.

View

Weikersheim WWTP

The newly built SBR plant of Weikersheim operates four SBR reactors. The control should ensure an energy efficient operation, stabilise the outlet values on a low level and use as little precipitation agents as possible.

View

Gotha WWTP

The wastewater treatment plant in the city of Gotha, located in the county of the same name, has been built in 1993 and treats the wastewater of the city of Gotha as well as of surrounding villages. At the time of its construction it was...

View

Locations and Contact

Asia

Aqseptence Group Co. Ltd., Hangzhou

Sales and Manufacturing Location
8 Chengye Road,
Binjiang District Hangzhou
Zhejiang Province, 310053
China

Tel: +86 0571 86698098

Fax: +86 0571 86698066

info.cn@aqseptence.com

Asia

Aqseptence Group FZCO, Dubai

Sales Location
East Side 5EA, 7th floor, 722
P.O. Box 371082
Dubai Airport Free Zone
United Arab Emirates
United Arab Emirates

Tel: +971 42278456

watertreatment@aqseptence.com

Australia

Aqseptence Group Pty Ltd., Brisbane

Sales and Manufacturing Location
88 Brickyard Road,
Geebung 4034 QLD
PO Box 85, Virginia DC,
QLD 4014
Australia

Tel: +61 7 3867 5555

Fax: +61 7 3867 5566

info.johnsonscreens.au@aqseptence.com

Europe

Aqseptence Group GmbH, Rimpar

Sales Location
Kettelerstrasse 5 -11
97222 Rimpar
Germany

Tel: +49 9365 8082 60

Fax: +49 9365 8082 50

info.intech@aqseptence.com

Europe

Aqseptence Group GmbH, Aarbergen

Sales and Manufacturing Location
Passavant-Geiger-Strasse 1
65326 Aarbergen
Germany

Tel: +49 6120 280

Fax: +49 6120 28 2182

info.passavant@aqseptence.com

Explore our portfolio

Show